LX-801-4 fire alarm control panel control panel 1.Input voltage: 240VAC (50Hz/60Hz) +/-10% 2.Battery: 24VDC3.Charging voltage protection: 1.6Ah glass fuse4.Sounder output: 24V nominal
LX-904 fire alarm bell bell Technical parameters 1. Base material: A>iron base Size: Φ100mm/150mm B>aluminium base Size: Φ150mm/200mm 2.Operating voltage: D
LX-901 fire siren siren Technical parameters 1.Voltage: 24VDC (50mA) 2.Voltage: 12VDC (100mA) 3.Sound: 100dB +/- 5dB (at 24VDC, 1 meter) 4.Strobe: 8,000mcd, six super
LX-231A fire alarm alarm Technical Parameters 1. Battery: 6F22 9V 2. Working temperature: -5- 65degree 3. System power supply voltage: +12VDC 4. Static current: 0mA 5.
LX-504 manual break glass break glass Technical Parameters 1. Voltage range: 9-24VDC 2. Static current: ≤10mA 3. Alarm current: ≤20mA 4. Working temp: -5-+65degree 5. Wo
LX-501 manual call point call point Technical Parameters 1. Installation environment: indoor or dry occasion 2. Maximum current allowed: 3A 3. Maximum voltage allowed: 50V 4.
LX-212 wire gas detector gas detector Technical Parameters 1. Power Source:220V AC 2. Sensitivity:10%LEL 3. Power Consumption:1.7W 4. Operation Temperature: -10-50degree 5. W
LX-235 ionization smoke alarm smoke alarm 1.static current: ≤12uA 2.Alarm current: ≤15mA 3.Operating voltage:DC 9v 4.Audio alarm: 85db at 10 feet 5.Tem. Range:-10 - +60 6.Hu
LX-229 conventional smoke alarm smoke alarm Technical parameters 1.Votage range:16-32 VDC 2.Alarm current:10-100mA 3.Quiescent:35uA @ 24VDC 4.Storage temperature:-20 to +75 5.Operat
LX-228 conventional heat detector heat detector Technical Parameters 1.Voltage:12VDC 30VDC 2.Alarm temperature: 65degree 3.Static current:40μA 80μA 4.Working humidity:10 90% 5.
LX-224 photoelectric smoke detector(stand alone) SMOKE DETECTOR Technical Parameters 1. Battery: 9V DC or AC110, 220V AC 2. Alarm sonority: ≥85db 3. Static current: <10μA 4. Alarm current:
LX-222 photoelectric smoke detector(stand alone) smoke detector 1.Photoelectricsensor 2.Powersupply:DC9Vbattery 3.Optioncurrent:20μA 4.Alarmcurrent:10mA 5.Alarmsonority:≥85db 6.Stakeoutar
LX-708 emergency exit sign exit sign 1. AC/DC operated 2. Material: fire retardant ABS plastic 3. Light source: red LED or green LED 4. Battery: 4.8V 650mAh NI-CD batteries 5.
LX-705 emergency exit sign EMERGENCY EXIT SIGNS Technical Parameters 1. AC/DC operated 2. LX-705R: red color 3. LX-705G: green color 4. Material: fire retardant ABS plastic 5.
LX-702 rechargeable emergency exit sign Emergencyexit signs Technical Parameters 1. Input voltage: 220 to 240V AC, 50/60Hz 2. Output power: 5W 3. Light source: super bright LED 4. Light int
LX-608 rechargeable emergency light EMERGENCY LIGHT Technical Parameters 1. Wall or ceiling mounting 2. Voltage:110V/277V 3. Lamps:2x5W 4. Lead-acid Battery 6V 4.5AH 5. Emergency durati
LX-607 rechargeable emergency light EMERGENCY LIGHT Technical Parameters 1. Rechargeable 6V, 4AH sealed lead acid battery 2. 2 x 10W fluorescent tubes 3. Emergency and automatic light-u
LX-605-30 rechargeble LED emergency light LED EMERGENCY LIGHT Technical Parameters 1. Built-in 6V, 4.0Ah lead-acid battery 2. Using 30 pieces LED 3. Strong or weak brightness can be chosen to
LX-604 fluorescent emergency light emergency light Technical Parameters 1.Wall and ceiling mounting 2.1x8W T5 fluorescent tube. 3.Power supply: AC220V±10% 4.Nickel cadmium batte
LX-602 fluorescent emergency light emergency light Technical Parameters 1.Wall and ceiling mounting 2.1x8W T5 fluorescent tube. 3.Power supply: AC220V±10%. 4.Nickel cadmium batt